1、地源热泵只做热源,冷源由其他的冷机供应
2、带热回收的地源热泵
3、四管制的地源热泵
4、地源热泵+蓄冷+蓄热
上述单独四种情况使用eQUEST提供的两管制热泵模型都无法解决。
近期我就遇到了一个项目,包含了2、3、4三种情形。该项目采用3台四管制地源热泵机组,2台带热回收的热泵机组,并且还使用了蓄冷和蓄热技术。系统设计相当复杂。以前的经验,对于这些情形我采用制冷模型和制热模型分开模拟的方式,也就是一个模型只模拟制冷工况,另一个模型只模拟供热工况,但是显然模拟过程很繁杂,结果数据也需要进行后处理,如果递交LEED模拟,还需要把你的模拟方法以及数据后处理的方法做很详细的说明。所以我就就开始研究看看有没有一种更简便的方法模拟,之前制冷制热模型分开的思路是:在制冷模型中采用冷机模拟地源热泵的制冷工况,然后在制热模型中使用热泵机组供热。但是由于热泵机组只能连接2-pipe类型的管路,所以导致制冷制热无法在同一个模型中。如果存在一个热泵机组可以连接热水管路(Hot water loop),那么制冷模型和制热模型就可以在一个模型中。于是我通过查阅eQUEST帮助文档注意到loop to loop heat pump系统。描述如下:
This chiller is attached to a both a chilled-water loop and a hot-water loop (Figure 30). The chiller actively supplies cooling and/or heating to the two loops. A lake/well water loop supplies the necessary heat balance via two heat-exchangers in series with the evaporator and condenser loops.
The chiller requires both evaporator and hot-water pumps, and these pumps must be able to operate independently of the chilled and hot-water loops. For this reason, the chilled-water and hot-water loops must have their own pumps, in addition to the chiller pumps. The evaporator and condenser pumps operate in a constant-flow mode, variable-flow operation is not permitted. However, the circulation-loop chilled-water and hot-water loop pumps may be either constant-flow or variable-flow.
The lake/well-water loop (condenser loop) interfaces with the two heat-exchangers. It can be pumped identically as described for other chillers. Most commonly, the lake/well loop will have its own pump. However, the chiller may have a condenser pump in addition to, or in lieu of, the well pump. If the condenser pump is in lieu of a pump directly attached to the lake/well loop, then it will power the loop. Otherwise it will act only to overcome the head of the chiller’s heat-exchangers. The condenser flow may be modulated using either two-way or three-way valves, the default is two-way, resulting in variable –volume condenser flow.
具体操作如下(以我上面提到的项目为案例):
1、建立3台离心冷机和2台热回收冷机,用于模拟地源热泵的制冷工况。并且用Thermal storage(Cold water tank) 模拟蓄冷系统。同时将热回收的loop连接到生活热水,eQUEST界面如下:
2、创建4台loop to loop heat pump,这里并应该是5台,但是由于一个loop只能最大连接10台设备,所以这里把CH4和CH5合并。并用Thermal storage(Hot water tank) 模拟蓄热系统。注意:由于loop to loop Heat pump需要连接制冷和制热都连接管路,因此我们这里虽然模拟的制热工况,但是制冷管路也要连接,等下我们使用设备控制器保证这个热泵不会制冷。
3.创建设备控制器,确保只有冷机进行制冷,热泵不制冷。